Hello #Astral users, Have you ever come across the ion foil adjustment failure error?? We have started seeing it since the tune was upgraded to 2.2 recently during the PM. The error interferes with the system getting ready to run a sample in the step where astral mass accuracy is checked with ICS.

One of the most overlooked factors in maintaining consistent, high-quality spray in nano-scale liquid chromatography is something you handle every time you connect your column: your capillary fitting. Thankfully, a little care & a few simple habits go a long way. Here's what to know: bit.ly/4zbjHd4

Caring for your capillary fitting: small habits for stable spray

One of the most overlooked factors in maintaining consistent, high-quality spray in nano-scale liquid chromatography is something you handle every time you connect your column: your capillary fitting ...

bit.ly

A question to mass spectrometrists in the core facilities around the UK and Europe.. How are you finding the cost of S-traps for proteomics applications?? It looks like incorporation of S-traps in the workflow adds an additional £8 per sample.. It feels extraordinarily expensive..

Never been a fan of the so-called number game.. However, it is indeed exciting when you get to see 100 precursors identified per second from biological samples, not just from a std digest.. Pretty stoked by having a front raw seat to witness the technology evolution through ages..😊😊 #MassSpecMusings

#TeamMassSpec, may I please check if there is a lab where Thermo #Ardia is seamlessly connected to multiple mass specs and process proteomics data processing and management on the server itself?? If yes, can I please have a brief chat?? I am interested in hearing more about it.. Thanks very much..

Is there any option to remove the contaminant proteins prior to normalisation in #Spectronaut?? Essentially, I would like to identify them, but don't want to include their abundance values for cross run normalisation.. is there a possibility?? Thanks very much..

Setting up a decent DDA method on Astral is so mentally taxing.. It isn't meant to follow any of the data dependency criteria.. Enforcing it to follow the criteria is where it gets taxing.. Wonder how it is working for those MS2-TMT workflows.. 🤔🤔

Today at 13:50, on the dot, the sequences running on both Ascend and Eclipse came to an abrupt stop.. Just at random.. In the middle of a run.. Neo kept running but no MS acquisition.. Had to restart Xcalibur and reconnect LC to resume the sequence.. Very spooky!!! #MassSpecMusings

Anybody doing proteomics on FACS sorted cells? People are using BSA coated tubes to avoid cell adhesion onto the walls. BSA is all over the protein extract. How to avoid this BSA? Saw Polyvinyl alcohol (PVA) can be used in place of BSA. Any experience with its compatibility for downstream MS? Thanks

"This work provides insight to help future proteomics study designers make more informed decisions on whether physical normalization is necessary for their experiments" Guess I am that old rigid mass spectrometrist now who finds it hard to keep an open mind to new concepts.. 😉😉

PastelBio@pastelbio.bsky.social · 7mo ago

Is Protein Quantification and Physical Normalization Always Necessary in Proteomics? www.biorxiv.org/cont... --- #proteomics #prot-preprint

#TeamMassSpec Question for XL-MS practitioners.. Looking for a suitable crosslinker to stabilise a protein complex in vitro.. What are the pros and cons for MS-cleavable vs non-cleavable cross-linkers?? Is PhoX a good choice?? Any recommendations for MS-cleavable cross-linkers?? Thanks very much..

(J Proteom) Two-dimensional electrophoresis-based proteomics reveals soybean seed hypocotyl proteoforms: Publication date: Available online 17 January 2026 Source: Journal of Proteomics Author(s): Jian-Zhong Tan, Hiroyuki Kagawa, Keiko Kizawa, Hisashi Hirano #MassSpecRSS

Two-dimensional electrophoresis-based proteomics reveals soybean seed hypocotyl proteoforms

Publication date: Available online 17 January 2026 Source: Journal of Proteomics Author(s): Jian-Zhong Tan, Hiroyuki Kagawa, Keiko Kizawa, Hisashi Hirano

dlvr.it

Vanquish Duo as Neo Mono with EasySpray column setup.. Works quite alright.. Guess have to get uPAC to test the dual column setup at nano flow rate..

Chromatogram reproducibility for HeLa QC
Bini Ramachandran @itsbinir.bsky.social · 9mo ago

#TeamMassSpec Can someone please help me remember whether the Vanquish Duo launched at ASMS2024 was meant for nanoLC applications?? Somehow, I remember it as the potential high speed solution from Thermo for Astral high SPD applications.. However, the Duo I got hold of here is a microflow version!!